Solid State Relays G3@-VD G3F/G3FD CSM_G3F_G3FD_DS_E_5_1 International Standards for G3F Series, Same Profile as MY Power Relays * Shape-compatible with mechanical relays. * Certified by UL, CSA, and VDE (model numbers with a suffix of "-VD"). * Socket type, same size as MY Power Relays. * Operation indicator provided to confirm input (model numbers with "N" before the suffix). Refer to Safety Precautions on page 6. Note: The socket is optional. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G3F-@@@@@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3F: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 3. Rated Load Current 02: 2A 03: 3A 4. Terminal Type S: Plug-in terminals 5. Zero Cross Function Blank: Equipped with zero cross functions L: Not equipped with zero cross function 6. Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator 7. Certification VD: Certified by UL, CSA, and VDE G3FD-@@@@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3F: Solid State Relay 2. Load Power Supply Type D: DC 3. Rated Load Power Supply Voltage X: 50 VDC 1: 100 VDC 4. Rated Load Current 02: 2A 03: 3A 5. Terminal Type S: Plug-in terminals 6. Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator 7. Certification VD: Certified by UL, CSA, and VDE 1 G3F/G3FD Ordering Information List of Models Isolation Photocoupler Zero cross function Yes Indicator Yes Rated output load Rated input voltage Model 3 A at 100 to 240 VAC (See note 1.) 5 to 24 VDC G3F-203SN-VD 2 A at 100 to 240 VAC (See note 1.) 100/110 VAC G3F-202SN-VD 200/220 VAC Phototriac coupler No 3 A at 100 to 240 VAC (See note 1.) 5 VDC G3F-203SLN-VD 12 VDC 24 VDC Photocoupler 3 A at 4 to 48 VDC (See note 2.) 5 to 24 VDC G3FD-X03SN-VD 2 A at 5 to 110 VDC 100/110 VAC G3FD-102SN-VD 200/220 VAC 5 to 24 VDC Photocoupler Yes Phototriac coupler No No 3 A at 100 to 240 VAC (See note 1.) 4 to 24 VDC G3F-203S-VD 5 VDC G3F-203SL-VD 12 VDC 24 VDC Photocoupler 3 A at 4 to 48 VDC (See note 2.) 4 to 24 VDC 2 A at 5 to 110 VDC G3FD-X03S-VD G3FD-102S-VD Note: 1. Product is labelled "240 VAC". 2. Product is labelled "48 VDC". 3. When ordering, specify the rated input voltage. Accessories (Order Separately) Connecting Sockets/Hold-Down Clips Front-mounting Sockets Back-mounting Sockets Socket PYF08A(-E) PYF08M PY08-02 PY08(QN) Hold-down Clip PYC-A1 PYC PYC-P PYC-P PYC-P PYC-S 2 G3F/G3FD Specifications Ratings (at an Ambient Temperature of 25C) Input Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage G3F-203SN-VD G3F-202SN-VD 5 to 24 VDC 4 to 28 VDC Must release voltage 15 mA max. (See note.) 4 VDC max. 1 VDC min. 20 VAC min. 100/110 VAC 75 to 125 VAC 41 k20% 75 VAC max. 200/220 VAC 150 to 250 VAC 72 k20% 150 VAC max. 40 VAC min. 5 VDC 4 to 6 VDC 390 20% 4 VDC max. 1 VDC min. 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 k20% 19.2 VDC max. G3FD-X03SN-VD 5 to 24 VDC 4 to 28 VDC 1.5 k+20%/-10% 4 VDC max. G3FD-102SN-VD 5 to 24 VDC 4 to 28 VDC 1.5 k+20%/-10% 4 VDC max. 100/110 VAC 75 to 125 VAC 41 k20% 75 VAC max. 200/220 VAC 150 to 250 VAC 72 k20% 150 VAC max. G3F-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max. (See note.) 3 VDC max. G3F-203SL-VD 5 VDC 4 to 6 VDC 390 20% 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 k20% 19.2 VDC max. 4 to 24 VDC 3 to 28 VDC 1.5 k+20%/-10% 3 VDC max. G3F-203SLN-VD G3FD-X03S-VD 20 VAC min. 40 VAC min. 1 VDC min. 4 VDC max. G3FD-102S-VD Note: 1. The input impedance is given for the maximum operating range. For details, refer to the Technical Guide for Solid State Relays. 2. Constant-current input circuit. Output Model G3F-203SN-VD G3F-203SLN-VD G3F-203S-VD G3F-203SL-VD Rated load voltage 100 to 240 VAC Applicable load Load voltage range 75 to 264 VAC Load current Inrush current 0.1 to 3 A at 40C 45 A (60 Hz, 1 cycle) G3F-203SN-VD 100 to 240 VAC 75 to 264 VAC 0.1 to 2 A at 40C 45 A (60 Hz, 1 cycle) G3FD-X03SN-VD G3FD-X03S-VD 4 to 48 VDC 3 to 52.8 VDC 0.1 to 3 A at 40C 18 A (10 ms) G3FD-102SN-VD G3FD-102S-VD 5 to 110 VDC 3 to 125 VDC 0.1 to 2 A at 40C 10 A (10 ms) 3 G3F/G3FD Characteristics Item G3F-203SN-VD G3F-202SN-VD G3F-203S-VD G3F-203SLN-VD G3F-203SL-VD G3FD-X03SN-VD G3FD-X03S-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) 1/2 of load power 2 ms max. source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 0.5 ms max. G3FD-102SN-VD G3FD-102S-VD 0.5 ms max. (DC input) 0.5 ms max. 20 ms max. (AC input) 2.5 ms max. (DC input) 2.5 ms max. 20 ms max. (AC input) 1.5 V max. Leakage current 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) 2.5 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) 5 mA max. (at 50 VDC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 1,000 m/s2 Ambient temperature Operating: -30C to 80C (with no icing or condensation) Storage: -30C to 100C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards G3F: UL508, CSA C22.2 No. 14, EN60947-4-3 G3FD: UL508, CSA C22.2 No. 14, EN60950-1 EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Weight Approx. 50 g 0.1 mA max. (at 100 VDC) 0.1 mA max. (at 100 VDC) 1,500 VAC, 50/60 Hz for 1 min 4 G3F/G3FD Engineering Data Load Current vs. Ambient Temperature Characteristics G3F-202SN-VD G3FD-102SN-VD/102S-VD Load current (A) Load current (A) G3F-203SN-VD/203S-VD/203SLN-VD/ 203SL-VD G3FD-X03SN-VD/X03S-VD Ambient temperature (C) Ambient temperature (C) One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) Inrush current (A. Peak) Inrush current (A. Peak) G3FD-102SN-VD/102S-VD Inrush current (A. Peak) G3FD-X03SN-VD/X03S-VD G3F-203SN-VD/203S-VD/202SN-VD/ 203SLN-VD/203SL-VD 10 20 Energized time (ms) Energized time (ms) Energized time (ms) Dimensions Note: All units are in millimeters unless otherwise indicated. Terminal Arrangement/ Internal Connections 28 max. 1 4 5 8(+) 9 Load Load (+) Load power supply 12(-) ( ) (-) 21.5 max. 13 36.5 max. Input 14 - 42.5 max. - + Input voltage + Note: The plus and minus symbols shown in parentheses are for DC loads. The load is possible to connect either + side or - side. 5 G3F/G3FD Safety Precautions Refer to Safety Precautions for All Solid State Relays. Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Connection The SSR for DC switching use can connect to a load regardless of the polarity of the positive and negative output terminals. Close Mounting of Multiple Relays If multiple Relays are mounted side by side, be aware that the outer wall of each SSR works as a heat sink. The SSR casing serves to dissipate heat. Install the Relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Protective Terminal When using for AC inductive loads, connect the load terminals of the SSR to an inrush absorber (varistor). EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions ("-VD" models only). Less than 3 m Load Input G3F-VD Output Varistor: 470 V, 0.6 W Film capacitor: 1 F, 250 VAC Varistor Film Capacitor * Connect a varistor between the output terminals. * Connect a film capacitor to the load power supply. * The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions ("-VD" models only). Less than 10 m Load Input G3FD-VD Output * The input cable must be less than 10 m. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3F-203SN DC5-24 G3FD-X03SN-DC5-24 G3F-202SN AC100/110 G3F-203S-DC3-28 G3F-203SLN DC24 G3FD102SN AC100/110 G3FD-X03S-DC3-28 G3FD-102-SN-DC5-24 G3FD-102SN-VD DC5-24 G3FD-X03SN-VD DC5-24 G3F-203SL DC24 G3FD-102SN AC200/220 G3FD-102SN-DC5-24 G3FD-X03S-VD DC4-24 G3FD-102SN-VD AC100/110 G3F-202SN-VD AC100/110 G3F-203SN-VDDC5-24